PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor
Por um escritor misterioso
Last updated 11 abril 2025
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://d3i71xaburhd42.cloudfront.net/7b94d8a453e271d33353bd167948fade772757ee/3-Figure1-1.png)
For the first time a robust alternative test method of SPF- and UVA-PF values is described, taking into account the interaction of sunscreen formulation and skin, and due to the elimination of any erythemal relevant UVB and U VA doses, absolutely no skin reaction occurs. Background/Aims: In order to define a label sun protection factor (SPF) of topically applied sunscreens, in vivo test methods like ISO 24444, FDA guideline, or the Australian standard are used worldwide. The basis of all these methods is provoking an erythemal skin reaction by UV irradiation to find the level of unprotected and protected minimal erythemal doses (MED). In vitro methods replacing the human skin by any kind of non-human material are still not available. Thus, offering the new hybrid diffuse reflectance spectroscopy (HDRS) technique that is able to stay on an in vivo level for SPF testing but meanwhile neglecting the UV-dose-related erythemal skin reaction is a perfect combination to take care of sun protection and any ethical concerns in SPF testing nowadays. Methods: HDRS is a combination of in vivo diffuse reflectance spectroscopy (DRS) measurements on the skin and in vitro transmission measurements of a sunscreen on a roughened polymethylmethacrylate plate. By this technique, the in vivo behavior of the investigated sunscreen on the skin is measured as well as the UVB absorption, which is still non-visible in the reflectance technique. In order to establish an alternative method for in vivo SPF testing, a huge number of sunscreens (80 samples) was measured by HDRS and compared to the worldwide accepted standard ISO 24444. The variety of sunscreens measured reflects a wide range of different types of formulations as well as a wide range of SPFs (5–120) to validate this new alternative SPF testing procedure. Results: The applied quantity of product as well as skin color dependencies of signal generation are shown to support any basic correlation of DRS signal generation and sun protection expectations. Far-reaching statistical data analyses show an excellent link of the new non-erythemally driven HDRS-SPF technique and ISO 24444 results. In the same way, HDRS-UVA-PF results can be correlated with UVA-PF values calculated from ISO 24443. Conclusion: Due to the elimination of any erythemal relevant UVB and UVA doses, absolutely no skin reaction occurs. Consequently there is no need to define a MED any more. For the first time an alternative way to SPF is shown without any ethical concerns of SPF testing in vivo and/or any restriction of SPF testing in vitro. Regardless of the type of formulation or the level of protection, an excellent correlation of SPFHDRS and SPF24444 for sunscreen labeling could be found. By this new alternative non-erythemal technique, not only SPF values can be measured, but also UVA-PF values can be calculated with an excellent correlation to ISO 24443 from the same set of data. For the first time a robust alternative test method of SPF- and UVA-PF values is described, taking into account the interaction of sunscreen formulation and skin.
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://i1.rgstatic.net/publication/6759129_Influence_of_Applied_Quantity_of_Sunscreen_Products_on_the_Sun_Protection_Factor_-_A_Multicenter_Study_Organized_by_the_DGK_Task_Force_Sun_Protection/links/00b49529eedc747de6000000/largepreview.png)
PDF) Influence of Applied Quantity of Sunscreen Products on the Sun Protection Factor – A Multicenter Study Organized by the DGK Task Force Sun Protection
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://onlinelibrary.wiley.com/cms/asset/d64eab07-7b60-4029-b692-925bcbfef517/phpp12703-fig-0004-m.jpg)
Multi‐laboratory study of hybrid diffuse reflectance spectroscopy to assess sunscreen SPF and UVA‐PFs - Ruvolo - 2021 - Photodermatology, Photoimmunology & Photomedicine - Wiley Online Library
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://d3i71xaburhd42.cloudfront.net/412f4ee7284bc9023a4eb2befca7f937b45701f0/2-Figure1-1.png)
PDF] A physically-based human skin reflection model
Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor - Document - Gale OneFile: Health and Medicine
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://i1.rgstatic.net/publication/42768827_How_a_calculated_model_of_sunscreen_geometry_can_explain_in_vitro_and_in_vivo_SPF_variation/links/57fc981208ae6ce92eb2c54f/largepreview.png)
PDF) How a calculated model of sunscreen geometry can explain in vitro and in vivo SPF variation
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://media.springernature.com/lw685/springer-static/image/art%3A10.1186%2Fs12951-022-01292-1/MediaObjects/12951_2022_1292_Fig4_HTML.png)
Zinc-metal–organic frameworks with tunable UV diffuse-reflectance as sunscreens, Journal of Nanobiotechnology
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://0.academia-photos.com/attachment_thumbnails/92495560/mini_magick20221015-1-1mdubbg.png?1665872158)
PDF) In vitro measurement of sun protection factor of sunscreens by diffuse transmittance
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://ars.els-cdn.com/content/image/1-s2.0-S0165993622002072-gr3.jpg)
Sunscreen testing: A critical perspective and future roadmap - ScienceDirect
![PDF] Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor](https://patentimages.storage.googleapis.com/45/2c/e7/f89b22d6df99a8/00070002.png)
EP1291640A1 - In vitro test method to assess the UVA protection performance of sun care products - Google Patents
Recomendado para você
-
Ex vivo - Wikipedia11 abril 2025
-
Vivo V23 5G Photography Test: A Promising Set of Shooters11 abril 2025
-
How to Test Human-Specific Combination Immunotherapies In Vivo11 abril 2025
-
Android 11 Update available for Vivo S1. Vivo V15 Pro (Greyscale Test)11 abril 2025
-
In Vivo Tests - Mérieux NutriSciences11 abril 2025
-
In Vitro vs In Vivo Preclinical Studies11 abril 2025
-
Vivoo 2.0, Advanced Urine Test Strips with App, at Home Urine Test Strips for Keto Test, Calcium, Vitamin C, Proteins, Salinity, Hydration, and More11 abril 2025
-
A diagram depicting in vivo and in vitro testing Stock Photo - Alamy11 abril 2025
-
Charging Compatibility Test vivo 80W Flash Charge (Dual USB-C) - Chargerlab11 abril 2025
-
Vivo X90 Pro camera test: Dimensity 9200 shows off its power - Phandroid11 abril 2025
você pode gostar
-
Toys, Forbidden Island Board Game11 abril 2025
-
Celular Samsung Galaxy S23 Ultra 5G 256GB Verde11 abril 2025
-
Katekyo Hitman REBORN DVD OVA Rebo Chara Collection 2 Character OAV from Japan11 abril 2025
-
Gabe Newell Memes - Imgflip11 abril 2025
-
Yu-Gi-Oh! ZEXAL - Rotten Tomatoes11 abril 2025
-
Comunidade Steam :: Rival Stars Horse Racing11 abril 2025
-
Pokemon Lugia's Ocean Parts Gameplay (GBA Rom Hack)11 abril 2025
-
Breynz The Zombie Werewolf11 abril 2025
-
Hitman 3's Free Starter Pack Grants Free-to-Play Access to Parts11 abril 2025
-
Cadillacs and Dinosaurs de Mega Drive ganha novidades11 abril 2025